Ultra 5 offers the ultimate flexibility in ultrasonic control and measurement. Like Ultra 3, Ultra 5 is user-configurable to measure level or volume, provide advanced pump control or measure open channel flow to BS ISO 1438 and 4359. Over and above the facilities offered by Ultra 3, Ultra 5 gives you the ultimate flexibility of: five assignable relays with extra alarm options such as pump efficiency; extra pump control functions including pump run-on and pump exercising; storm and aeration control; differential control using two transducers, the addition of further relays in OCM applications.
Ultra 5 features the benefit of DATEM, the world’s most advanced echo processing software, for reliable level measurement.
Level
All the features of the Ultra 3 with 2 additional relays. Offers optional 4 -20mA input for a pressure transmitter or similar.
Volume
All the features of the Ultra 3 with 2 additional control/alarm relays.
Pump control
Ultra 5 in pump control configuration is a premium specification ultrasonic pump control unit offering many standard features. Advanced control functions include:
Pump run-on, allowing the user to set both the run-on interval and the duration, for periodic pumping past the off point to remove solids from pump stations.
Pump exercising, causes pumps to come on when a period of non operation has occurred, idle time and exercise time can be set.
Start point variation, reduces material build up on the walls at the ‘normal’ level by setting a band in which the switch point varies.
Storm control feature permits the identification of a storm condition and operate any relay with specific points being set to accommodate needs during a storm, and the ability to disable other relays during the storm if required.
Aeration control activates on elapsed time (since pumps ran), in little used well. Introduces air to reduce well gases.
Flush valve control activates a re-circulation valve for a specific time based on pump cycle frequency, Prevents solids settling.
Data logs
Running total of individual pump running hours. Running total of individual pump starts. Running total of individual pump run-ons.
Differential
Ultra 5 offers further sophistication with the inclusion of differential level capability using two transducers. With one upstream and the other downstream of a screen or penstock, an alarm or control signal is initiated as the difference between the level exceeds a user- defined limit to automatically operate the cleaning mechanism.
Open Channel Flow
All the features of the Ultra 3 with 2 additional relays. With the additional step/time control for use with a penstock.
A data logging board is an optional extra with RS485 connection and large data log capability together with Profibus DP V0 and V1 or Modbus communications.
Ultra 5 offers the ultimate flexibility in ultrasonic control and measurement. Like Ultra 3, Ultra 5 is user-configurable to measure level or volume, provide advanced pump control or measure open channel flow to BS ISO 1438 and 4359. Over and above the facilities offered by Ultra 3, Ultra 5 gives you the ultimate flexibility of: five assignable relays with extra alarm options such as pump efficiency; extra pump control functions including pump run-on and pump exercising; storm and aeration control; differential control using two transducers, the addition of further relays in OCM applications.
Ultra 5 features the benefit of DATEM, the world’s most advanced echo processing software, for reliable level measurement.
Level
All the features of the Ultra 3 with 2 additional relays. Offers optional 4 -20mA input for a pressure transmitter or similar.
Volume
All the features of the Ultra 3 with 2 additional control/alarm relays.
Pump control
Ultra 5 in pump control configuration is a premium specification ultrasonic pump control unit offering many standard features. Advanced control functions include:
Pump run-on, allowing the user to set both the run-on interval and the duration, for periodic pumping past the off point to remove solids from pump stations.
Pump exercising, causes pumps to come on when a period of non operation has occurred, idle time and exercise time can be set.
Start point variation, reduces material build up on the walls at the ‘normal’ level by setting a band in which the switch point varies.
Storm control feature permits the identification of a storm condition and operate any relay with specific points being set to accommodate needs during a storm, and the ability to disable other relays during the storm if required.
Aeration control activates on elapsed time (since pumps ran), in little used well. Introduces air to reduce well gases.
Flush valve control activates a re-circulation valve for a specific time based on pump cycle frequency, Prevents solids settling.
Data logs
Running total of individual pump running hours. Running total of individual pump starts. Running total of individual pump run-ons.
Differential
Ultra 5 offers further sophistication with the inclusion of differential level capability using two transducers. With one upstream and the other downstream of a screen or penstock, an alarm or control signal is initiated as the difference between the level exceeds a user- defined limit to automatically operate the cleaning mechanism.
Open Channel Flow
All the features of the Ultra 3 with 2 additional relays. With the additional step/time control for use with a penstock.
A data logging board is an optional extra with RS485 connection and large data log capability together with Profibus DP V0 and V1 or Modbus communications.