Pulsar homepage logo
Excellence in level and flow measurement.
ISO 9001 registered.

Please note, if you are using Chrome as a browser some PDF downloads will not work unless you disable Chrome's PDF viewer.
Login | T: + 44 (0) 1684 891371
Cardinal Building,
Enigma Commercial Centre,
Sandy’s Road, Malvern, Worcestershire,
WR14 1JJ, England
Highly intelligent pump controller
Automatically resets tripped pumps
Time to spill calculation and warning
Easy prompt led set up
RS485 Modbus and Profibus DP V0 and V1 options
10 relay outputs and 7 digital inputs
Pump efficiency alarm function
Peak power tariff avoidance
Burst rising main and pump blockage alarm
PHYSICAL: 

Weight: 
Nominal 1.3kg
Case Material: 
Stainless steel and polycarbonate, flame resistant to UL94 V0 
Transduce cable requirement: 
Twin screened 
Maximum seperation: 
1000m 
Fascia mount: 
200mm x 112mm frontage, 165mm x 105mm cut out 
OPTIONS: 

Digital communications: 
RS485 Modbus or Profibus DP V0 or V1 
ENVIRONMENTAL: 

IP rating: 
IP64 
Max. and min. temperature (electronics): 
-20ºC - +50º 
Flammable atmosphere approval: 
Safe area; compatible with approved dB transducers allowing installation to zone 0 or zone 1 
CE Approval: 
EMC approval to BS EN 50081-1:1992 for emisssions and BS EN 50082-2:1995 for immunity, and to BS EN 61010-1:1993 for low voltage directive 
Power Supply: 
115V AC +5% - 10% 50/60Hz, 230 v AC +5% - 10% 50/60Hz, 18 - 36V DC 
PERFORMANCE: 

Accuracy: 
0.25% of the measured range or 6mm (whichever is greater) 
Resolution: 
0.1% of the measured range or 2mm (whichever is greater) 
Range: 
Dependant on transducer from 125mm to 50m 
ECHO PROCESSING: 

Echo Processing: 
Patented DATEM software 
INPUT/OUTPUT: 

Volt free contacts: 
10 in total; Relays 1 - 5 form C (SPDT) 5A, 240V AC, relays 6 - 10 form C (SPDT) 3A, 240V AC 
Digital Inputs: 
7 NO or NC with 24V DC internal supply, max. 20mA 
Analouge Output (adjustable), 0.1%: 
isolated output 4-20mA or 0-20mA into 500Ω (user programmable and adjustable 
Analogue Input: 
Isolated input for loop powered device 
Serial Output: 
RS232 via RJ11 port 
Display: 
6 digits plus 12 character text plus bargraph with direction indicators, remote Communicator identifier and program/run/test mode indicators 
ANALOGUE INPUT: 


4-20mA source (N.B. Active on request) 
PROGRAMMING: 

On-BoardProgramming: Standard with integral keypad 
PC Programming: 
Via RS232 (RJ11 port) 
Programming Security
Via password (user selectable and adjustable)
Programmed Data Integrity:
Via non-volatile RAM plus backup
Download Quantum datasheet here.
Download Quantum datasheet in French here.
Download Quantum datasheet in Spanish here.
Download Quantum manual here..